Sale!

Super Anchor 1055-SX 3/8″ Stainless HLL Cable – Per Foot

Original price was: $5.38.Current price is: $3.42.

55 in stock

SKU: 1055-SX Category:

Description

Super Anchor Safety HLL Cable

1055-SX Stainless 3/8 Inch HLL Cable by the Foot

The Super Anchor 1055-SX is the HLL wire rope the CRA lifeline system is engineered around: 3/8 inch 7×19 316 stainless steel cable with a 12,000 lb minimum tensile strength, sold by the foot and cut to your run length. Enter your footage as the quantity and one continuous length ships.

Let us provide a free custom quote for your Permanent Horizontal Lifeline project. HLL Quote Request Form

Cable ships cut to length as one continuous piece. Terminations build on site with eye thimbles and cable clamps per the 02-2021 rigging manual, or ask about factory swaged assemblies when ordering a complete system. Pairs with the 1051 series stainless rigging kits.

12,000 lbMinimum Tensile Strength7×19Aircraft Cable Construction3/8 inCable DiameterPer FtCut to Your Length120 ftTypical HLL Run45 ft-lbClamp Torque Spec0.24 lbWeight per Foot50 ftMinimum Order

Who Needs This Product

This cable is for crews rigging Super Anchor engineered horizontal lifelines: 120 ft typical runs on CRA or CRO anchors with pass-thru intermediates every 20 to 30 ft. The stainless 1055-SX is for coastal, chemical, and wash-down environments, and wherever the anchors and rigging are stainless. Wear gloves when handling wire rope and wrap or tape cut ends; cut wires cause puncture and laceration injuries per the rigging manual warning.

Features

12,000 lb minimum tensile

3/8 inch 7×19 construction rated for the 2-person arrest, 4-person restraint HLL system performance.

Sold by the foot

Order exactly the footage the run needs; quantity equals feet and it ships as one continuous length.

One continuous length

Your footage ships as a single uncut piece, ready to feed through pass-thru tops and terminate on site.

Field swage compatible

Terminates on site with eye thimbles and 3 cable clamps torqued to 45 ft-lb per the manual.

O-ring travel ready

No. 5010-SM connector O-rings ride this cable through pass-thru tops for hands-free travel.

316 stainless construction

Maximum corrosion resistance for coastal and corrosive sites.

Technical Specifications

Cable 3/8 inch diameter, 7×19 construction, 316 stainless steel
Minimum Tensile Strength 12,000 lb
Sold As Per foot, cut to length, one continuous piece per order; 50 ft minimum
Weight 0.243 lb per foot actual
Field Termination Eye thimble plus 3 cable clamps (No. 1056-S), saddles on live side, 10 inch dead side, 45 ft-lb
System Performance 2-person fall arrest or 4-person fall restraint per run; 310 lb users; 1,200 lb average peak force
Run Geometry Typically 120 ft, 130 ft maximum engineered; anchors 20 to 30 ft on center
Compliance System component per the 02-2021 CRA HLL Rigging Manual; ANSI Z359.1-07, OSHA 1926.502

Wire rope safety and engineering. Cut ends of wire rope cause puncture and laceration injuries; wear gloves and wrap cut ends with tape. HLL runs must be designed by a qualified or competent person with anchors, absorber, and terminations per the 02-2021 rigging manual. Never exceed 130 ft engineered run length, and replace the cable after any fall event.

Compliance Standards

ANSI Z359.1-07 / OSHA 1926.502

HLL cable specified by the 02-2021 CRA rigging manual complies as a system component.

7×19 Aircraft Cable Construction

133-wire construction balances strength with the flexibility field swaging requires.

Engineered System Basis

Runs typically 120 ft, 130 ft maximum with third-party engineering, anchors 20 to 30 ft on center.

Rigging Kit Matched

Thimbles and clamps for both terminations come in the 1050/1051 series rigging kits.

Typical Applications

HLL RunsPrimary cable for CRA/CRO engineered lifelines.Standing Seam SystemsRuns on 1207 plate anchored lifelines.Replacement CableRe-cabling existing SAS HLL installations.Multi-Run LayoutsFootage for T, 90, and 45 degree intersections.Coastal InstallationsStainless runs in corrosive salt air environments.Window Washing BuildingsRooftop lifeline cable.Solar FieldsRow-end to row-end continuous runs.Custom LanyardsCut lengths with factory assembly per the vendor worksheet.

Installation Overview

Ordering and terminating per the 02-2021 manual:

  1. Measure the run end anchor to end anchor and add termination allowance: approximately 40 inches of A-end component length plus a 10 inch field swage dead side.
  2. Order the footage cut to length; both terminations build on site per the rigging manual.
  3. Feed the cable through every pass-thru top and install the 4 No. 5010-SM O-rings before clamping.
  4. Build the field swage termination: eye thimble, 3 cable clamps with saddles on the live side, 10 inch dead side, clamps at 2.0 and 4.0 inch centers.
  5. Torque clamp nuts to 45 ft-lb with a calibrated wrench, alternating sides evenly, and wrap the cut end with exterior tape or shrink tube.
  6. Tension through the turnbuckle until the spring absorber gauge deploys fully, then re-verify clamp torque.

Inspection and Retirement

Inspect before installation and each use, with documented annual inspections. Remove the anchor from service when any of the following apply:

  • Broken wires, kinks, birdcaging, or crushed sections anywhere along the run.
  • Corrosion beyond surface staining (galvanized) or any pitting (stainless).
  • Field swage clamps missing, loose, or below 45 ft-lb torque.
  • The run was subjected to a fall; replace the cable and inspect all rigging.
  • Cut ends unwrapped or fraying past the clamps.

Tag anchors removed from service to prevent further use until inspected by a qualified or competent person.

Fall Protection
Distributors, LLC
Free Tool · No Signup · OSHA 1926.502
Free Interactive Tool Fall Protection Calculator Pick your system. Run the math. Generate a plan. 1Pick Your SystemDetermine fall restraint vs. fall arrest based on your work surface, edge access, and clearance. 2Run the MathCalculate exact fall clearance required below the work surface for your SRL or lanyard setup. 3Generate a PlanGet a printable OSHA-compliant Fall Protection Plan structured around 29 CFR 1926.502(k). Run the Numbers and Stay Safe Launch the Calculator ›

Frequently Asked Questions

How do I order the right length?Measure end anchor to end anchor, then add the termination allowance: roughly 40 inches of A-end components (turnbuckle, absorber, couplers) plus a 10 inch field swage dead side. Enter the total feet as the quantity; it ships as one continuous length. The specifications listed on this page outline the build details you need for your application.How are the ends terminated?On site, per the 02-2021 rigging manual: a No. 1057-S eye thimble with 3 cable clamps per termination, saddles on the live side, 10 inch dead side, torqued to 45 ft-lb. The rigging kits include the thimbles and clamps for both ends. Verify that the mounting surface is sound and that every fastener is fully seated before the anchor is put into service.Galvanized or stainless?Galvanized 1055-X (14,000 lb) is the standard for most exterior work. Stainless 1055-SX (12,000 lb) is for coastal, chemical, and wash-down sites, matched with the 1051 series stainless rigging kits and stainless clamps. See the Technical Specifications on this page for the exact materials, dimensions, and ratings.What else does a complete lifeline need?End anchors with loop tops, pass-thru intermediates every 20 to 30 ft, a rigging kit (turnbuckle, spring energy absorber, couplers, thimbles, clamps), 5010-SM O-rings for worker travel, and a layout by a qualified or competent person. Pair it only with connectors and equipment that are approved for use together so the complete system performs as designed.How many clamps per termination?Three, saddles on the live side, spaced at 2.0 and 4.0 inch centers with a 10 inch dead side, torqued to 45 ft-lb each with a calibrated wrench in two passes. A correct installation is critical, so confirm the setup matches the manufacturer instructions before any worker ties off.Can workers travel past the intermediate anchors?Yes, with No. 5010-SM O-rings installed on the cable before clamping; the rings pass through the 1091 pass-thru tops so workers move the full run without unclipping. Follow the recommended fastener pattern and placement so the connection is secure, and re-check the installation before you rely on it for fall arrest.When does the cable get replaced?After any fall event, and whenever inspection finds broken wires, kinks, birdcaging, crushed sections, or corrosion beyond surface staining. Inspect before each use along the full run. Inspect it before every use, and retire it right away if you find corrosion, cracks, or bent components.

Super Anchor 1055-SX Submittals and Documentation

CRA HLL Rigging Manual 02-2021 (PDF)Cable specifications, swaging procedures, torque values, and system rigging.CRA-PT Pass-Thru Catalog Pages (PDF)Intermediate anchor specifications for the posts this cable runs through.Super Anchor Warranty and Compliance Statement (PDF)Manufacturer warranty terms for Super Anchor fall protection equipment.

Compatible and Related Products

  • Super Anchor 1050-G HLL Rigging Kit. Terminations, absorber, and turnbuckle for CRA anchor runs.
  • Super Anchor 1031-PG Pass-Thru Anchor. Intermediate anchors the cable runs through.
  • Super Anchor 1032-W CRA 12″ Anchor Post. Loop top end anchors for the run.
  • Super Anchor 120 ft Standing Seam HLL Kit. Complete engineered system, cable included.

Cabling a Lifeline Run?

Send us the run length and anchor layout and we will spec the footage, assembly options, rigging kit, and anchors so the complete system ships together, based on the delivery location.

Call 863-703-4522 to talk to a fall protection specialist.