Description

Super Anchor Safety Hinge-2

3013-D Hinge-2 Adjustable Reusable Anchor, 3-Pack

The Super Anchor 3013-D Hinge-2 is the adjustable, reusable temporary anchor: 19 inches of 11 gauge steel with hinge shackles that adjust to the pitch, a forged dacromet coated D-ring, and a 5,000 lb minimum tensile strength. It mounts at the ridge or in the field, and unlike basic hinged anchors it can also anchor a self-retracting lifeline when attached with WS 3.0 hex head screws. This listing is a 3-pack.

One worker at up to 310 lb including tools, 6 ft maximum free fall, on slopes to 24/12 with WS 3.0 wood screws or 12/12 with 16d nails and 12 screws. Temporary only, removed after use. Compliant with OSHA 1926.502 and ANSI Z359.1-07 per the 2024 Hinge-2 manual.

5,000 lbMinimum Tensile Strength310 lbUser Capacity with Tools24/12Max Slope with WS 3.0 Screws19 inAnchor Length11 gaSteel with Forged D-Ring3xAnchors per PackSRLAnchorage CapableZ359.1ANSI Compliance

Who Needs This Product

The Hinge-2 is for roofing and solar crews who want one adjustable anchor across every pitch they work: the shackle hinge articulates for ridge or field mounting a minimum of 6 ft from any gable edge, over a minimum 2×4 top chord with 7/16 inch OSB sheathing. Each worker wears a full body harness with connectors carrying 3,600 lb gate strengths per current ANSI and CSA standards. Not for window washing, work positioning, or scaffolding tie-off, and never rig an HLL from nail-attached anchors.

Features

Adjustable hinge shackles

Welded shackle hinges articulate so the D-ring loads correctly on ridge or field mounts across pitches.

Forged dacromet D-ring

Forged, dacromet coated D-ring on 11 gauge steel with a 5,000 lb minimum tensile strength; 3013-S stainless version available for special order.

SRL anchorage capable

Anchors a self-retracting lifeline when attached with WS 3.0 hex head screws per the manual figures.

24/12 slope rating

WS 3.0 wood screws carry it to 24/12; 16d nails and 12 screws to 12/12.

Perimeter fastener holes

Multiple fastener locations lock the anchor to the framing through the sheathing.

Reusable 3-pack

Remove after use, inspect, and move to the next job.

Technical Specifications

Model Hinge-2 No. 3013-D
Package 3-pack
Material 11 gauge steel with forged dacromet coated D-ring (3013-S: 430 SST with 304 SST D-ring)
Length 19 inches
Minimum Tensile Strength 5,000 lb
User Capacity 1 person at 310 lb maximum including tools and equipment
Maximum Free Fall 6 ft
Maximum Slope 24/12 with WS 3.0 hex head wood screws; 12/12 with 16d nails or 12 screws
Mounting Ridge or field, minimum 6 ft from any gable edge; minimum 2×4 top chord with 7/16 inch OSB sheathing
Service Zones Fall arrest within 30 degrees of vertical center; fall restraint 360 degrees without free fall exposure
SRL Use Permitted with WS 3.0 hex head screw attachment per manual figures
Horizontal Lifelines Only when engineered per the Hinge-2 No. 1321 HLL manual; never with nail attachment
Compliance OSHA 1926.502; ANSI Z359.1-07
Structural Requirement 2 times the intended load or 5,000 lb without engineering

Sheathing required, and never HLL on nails. Do not attach the Hinge-2 directly to a top chord without sheathing installed. Horizontal lifelines require engineering per the Hinge-2 1321 HLL manual and must never run from nail-attached anchors. Match fasteners to slope, keep connectors at 3,600 lb gate strength, and remove the anchor after use.

Compliance Standards

ANSI Z359.1-07

Temporary anchorage compliance per the 2024 Hinge-2 manual.

OSHA 1926.502

Construction fall protection anchorage criteria with 5,000 lb structural support.

Forged Hardware

Forged dacromet D-ring with welded shackle hinges, inspection reference points marked.

SRL Rated Attachment

WS 3.0 hex head screw attachment rated for self-retracting lifeline anchorage.

Typical Applications

Steep Slope RoofingAdjustable anchor rated to 24/12 with WS screws.Tile LoadingRidge anchors during tile delivery and layout.Solar InstallationTemporary anchorage that moves with the crew.SRL Tie-OffScrew-attached SRL anchorage per the manual.Underlayment WorkField mounts on sheathed, papered decks.Storm and RepairFast reusable anchorage for short jobs.Fall Restraint360 degree restraint rigging without free fall.Engineered HLLsSpans per the Hinge-2 1321 HLL manual.

Installation Overview

Full figures and fastener specifications are in the manual linked below. The basics:

  1. Mount at the ridge or in the field, a minimum of 6 ft from any gable edge, over a minimum 2×4 top chord with 7/16 inch OSB sheathing installed.
  2. Choose fasteners for the slope: WS 3.0 hex head wood screws to 24/12, or 16d nails and 12 screws to 12/12.
  3. Drive fasteners through the perimeter holes into framing, with the shackle welds and D-ring oriented downslope.
  4. For SRL anchorage, attach with WS 3.0 hex head screws per the manual figures.
  5. Work within 30 degrees of vertical center for fall arrest, or rig 360 degree fall restraint without free fall exposure.
  6. Remove after use, inspect the shackle welds and D-ring, and redeploy on the next job.

Inspection and Retirement

Inspect before installation and each use, with documented annual inspections. Remove the anchor from service when any of the following apply:

  • The D-ring or shackle is deformed, or shackle welds show cracks.
  • The anchor body is bent or fastener holes are elongated.
  • The anchor was subjected to a free fall.
  • Corrosion is present that does not clean up.
  • The wrong fastener type was used for the slope or application.

Tag anchors removed from service to prevent further use until inspected by a qualified or competent person.

Fall Protection
Distributors, LLC
Free Tool · No Signup · OSHA 1926.502
Free Interactive Tool Fall Protection Calculator Pick your system. Run the math. Generate a plan. 1Pick Your SystemDetermine fall restraint vs. fall arrest based on your work surface, edge access, and clearance. 2Run the MathCalculate exact fall clearance required below the work surface for your SRL or lanyard setup. 3Generate a PlanGet a printable OSHA-compliant Fall Protection Plan structured around 29 CFR 1926.502(k). Run the Numbers and Stay Safe Launch the Calculator ›

Frequently Asked Questions

What makes the Hinge-2 different from a basic hinged anchor?The shackle hinge articulates to the pitch instead of a fixed fold, the D-ring is forged and dacromet coated, the slope rating extends to 24/12 with WS 3.0 screws, and it is rated to anchor an SRL when screw-attached. It is the anchor in Super Anchor MAX kits.Can I anchor an SRL to it?Yes, when the anchor is attached with WS 3.0 hex head screws per the manual figures. Nail-attached anchors are not rated for SRL anchorage. Verify that the mounting surface is sound and that every fastener is fully seated before the anchor is put into service.How close to the edge can I mount it?Keep a minimum of 6 ft from any gable edge, ridge or field mounted, with locations set by the job specific plan and free fall hazards identified. Verify that the mounting surface is sound and that every fastener is fully seated before the anchor is put into service.Can I run a horizontal lifeline between Hinge-2 anchors?Only as an engineered system per the Hinge-2 No. 1321 HLL manual, designed by a competent or qualified person, and never from anchors attached with nails. Verify that the mounting surface is sound and that every fastener is fully seated before the anchor is put into service.Is it reusable?Yes. It is a temporary anchor that removes after use and redeploys while it passes inspection: straight body, sound shackle welds, clean D-ring, and no fall history. Never modify or repair the product in the field, since altering it can compromise its ability to arrest a fall.What slope can I work on?Up to 24/12 with WS 3.0 hex head wood screws, or up to 12/12 with 16d nails or 12 wood screws, per the 2024 manual. A correct installation is critical, so confirm the setup matches the manufacturer instructions before any worker ties off. Keep the manufacturer instructions with the equipment so anyone using it can reference the approved procedures.What PPE pairs with it?A full body harness with snaphooks or carabiners carrying 3,600 lb gate strengths per current ANSI and CSA standards, on a vertical lifeline with rope grab and energy absorber, or an SRL on screw-attached anchors. A correct installation is critical, so confirm the setup matches the manufacturer instructions before any worker ties off.

Super Anchor 3013-D Submittals and Documentation

Hinge-2 3013-D/3013-S Instruction/Specification Manual 2024 (PDF)Specifications, slope and fastener requirements, mounting rules, SRL attachment, and inspection criteria.Hinge-2 Metal Deck Fastener Addendum 08-2020 (PDF)Type B metal deck fastener specifications for Hinge-2 anchors.Super Anchor Warranty and Compliance Statement (PDF)Manufacturer warranty terms for Super Anchor fall protection equipment.Horizontal Lifeline Manual (PDF)HLL system rigging, spans, and clearances.

Compatible and Related Products

  • Super Anchor 3013-D Hinge-2 Anchors. Adjustable reusable temporary anchor with forged D-ring.
  • Super Anchor 3006 Hinged Anchors. Value hinged temporary anchor 4-pack.
  • Super Anchor 4020 3-Strand Value Lifeline. Lifeline for temporary anchor tie-off.
  • Super Anchor 3200 50 ft Safety Kit. Complete roofers kit built on the Hinge-2 anchor.

Standardizing Your Crews on One Temporary Anchor?

Tell us your pitches, crew count, and SRL usage and we will spec Hinge-2 packs and lifelines so everything ships together, based on the delivery location.

Call 863-703-4522 to talk to a fall protection specialist.